葡京3522新地址-3522葡京集团-官方网站

葡京3522官方网站

$narry[1][alt]}

Products

Official WeChat

Contact Us

Shandong ShenYu machinery manufacturing co., LTD
FAX:-86-546-7793898
E-MAIL:sales@shenyu-group.com
ADD:Guang Ming road, the economic development zone of guangrao county, shandong province
Digital oilfield solutions

Motor protector

Detail Introduction

Specifications

1.motor protector : overload, overcurrent, phase failure, over voltage etc. 
2. measure volt, amp, watt, kwh 
3. Modbus/Profibus

Features:

 

1. Use module framework. Several modules can be selected flexibly.

 

 2. PMAC802 provides 12 protection functions such as start overtime protection, overload protection, overcurrent protection, phase failure protection, current unbalance protection, earth fault/leakage current protection, short circuit protection, underload protection, external fault protection, overvoltage protection, undervoltage protection, under power protection, phase sequence error protection, EEx e overload protection, temperature (PTC/NTC) protection, analog input protection.

 

 3. Provides measurements of three phases current, three phase /phase voltage, zero phase sequence current, active power, reactive power, power factor, frequency, and active energy measurements.

 

 4. Provides protection, direct starter, reversing direct starter, star/delta starter, and autotransformer starter etc motor starting control modes.

 

 5. Main module provides 9 DIs for start, stop and reset etc. signals input. If more DIs are needed, an extended digital module can be selected. Some of the DIs are programmable.

 

6. Main module provides 5 DOs to meet varies of starting control modes and protection action. If more DOs are needed, an extended digital module can be selected. Some of the DOs are programmable.

 

7. Provides 4~20mA analog output for DCS.

 

8. Through an extended analog module, 2 analog input or 1 analog and 1 hot resistance input can be added.

 

9. Small size and compact configuration.

 

10. Easy installation. Proper for 35mm DIN rail.

 

 

1. Protection:

Protection PMAC802 PMAC801
start overtime
Over load  √  √
Over current  √  √
Phase failure  √  √
Current unbalance  √  √
Short circuit  √  √
Earth fault  √  √
Under load  √  √
External fault  √  √
Leakage current  optional  optional 
Temperture ( PTC/ NTC)    optional
Over voltage  optional  optional
Under voltage  optional   optional
Under power    optional
Phase sequence error     optional
EEx e overload (tE)  optonal  optional
Analog input    optioanl

 

 

2. Measurement:

Parameters PMAC802     PMAC801    
3 phase current, neutral current, unbalance rate
3 phase voltage optional optional
active / reactive power optional optional
leakage current optional optional
power factor optional optional
 frequency optional optional
active energy (kwh) optional optional